Test item

Battery Voltage

Notes

MSR+ICC+

Contactless

250 times for MSR

4.18Và418->4.0911V

By using TS146 commands to turn on the MSR swipe function in loop.

250 times for ICC Card

4.0910Và30910->3.879V

By using TS146 commands to turn on the ICC function in loop.

300 times for Contactless Card

3.879Và3879->3.653V

By using TS146 commands to turn on the Contactless function in loop.

ICC

>1200 times for ICC Card

4.18Và3.09Và0V18->3.09->0V

By using TS146 commands to turn on the ICC function in loop (2sec/div) until out of battery.

P.S our unit always stay on Run Mode

Contactless

>650 times for Contactless Card

4.195Và3.71Và3195->3.71->3.55V

By Using IDT HW Test (iOS app)

  1. Each transaction took 15~20 sec.
  2. After 650 transaction times, battery voltage was closed to 3.71V; the green and amber LED will be blinking.
  3. Between 3.71V à 3.55V, the transaction would be effected by voltage dropping; we only can do less than 80 times

P.S FW Version: NEO v1.01.015.00D

...