Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

TagDefinitionLengthRecommended DefaultExampleDescription / Usage
DFEF62Controls whether MSR card with a chip on it can be swiped100DFEF6201000: Allows swipe from chip card. 1: Disallows swipe from chip card.
DFED0AOutputs Fallback Reason101DFED0A01010: Switch is off, does not output fallback reason. 1: Switch is on, does output fallback reason
DFEF65 Controls Error Reporting101DFEF6501010: Switch is off, does not output errors / mutes. 1: Switch is on, does output errors
DFEF62Controls whether MSR card with a chip on it can be swiped100DFEF6201000: Allows swipe from chip card. 1: Disallows swipe from chip card.
DFEF7D Controls the number of times the reader will allow another insert after a bad insert103DFEF7D0103

Configure up to 5 maximum times for the fallback. More information is available on the IDTECH KB:

Product Integration Topic - Augusta QuickChip KeyBoard fallback behavior

DFEF7E Controls the status messages returned by the device while the device is in fallback.650 01 50 05 50 36DFEF7E06500150055036Leave as the recommended default value.
DFEF5A Controls output of tags in QC KB modevariableSee belowSee below

This tag is utilized for the Augusta QC KB's output. The contents of the tag should include all tags that you'd like to see output on a successful dip.

We recommend that you put only the bare minimum necessary, as each tag added will increase the time spent / amount of information to process.

DFED20Company Name0-1669 64 74 65 63 68DFED2006696474656368

To use, Add this to the DFEF5A output (see further below) after you specify this in the terminal configurations.

Use this TLV for meta data for company name - recommended to use this to store some identifier to track who configured the device.


DFED21Configure Date3042018DFED2103042018

To use, Add this to the DFEF5A output (see further below) after you specify this in the terminal configurations.

Use this TLV for tracking the configuration date - recommended to use this to track date of config if the key injection / config are done at separate dates.

Noe that the output in HEX is the actual value, does not need to be converted.

DFED22Current Configuration Version / Misc field0-3268 65 6C 6C 6F 2D 74 68 69 73 2D 69 73 2D 69 64 74 65 63 68 2D 63 6F 6E 66 69 67 75 72 65 64 21DFED222068 65 6C 6C 6F 2D 74 68 69 73 2D 69 73 2D 69 64 74 65 63 68 2D 63 6F 6E 66 69 67 75 72 65 64 21

To use, Add this to the DFEF5A output (see further below) after you specify this in the terminal configurations.

Use this TLV for anything that might help you uniquely identify the terminal and device.


DFEF57FW Version for QC KBvariableN / ADF EF 57 0A 56 31 2E 30 32 2E 30 30 32 2A

To use, Add this to the DFEF5A output (see further below). This value will be pulled from the device.

DFEE17Terminal Entry Mode output control105DFEE170105This configured the output value for 9F39, which is the POS entry mode. If you include 9F39 in the DFEF5A tag, you can expect to see the contents of DFEE17 returned.

...

You can consult our guide on the IDTECH KB -

How Do I Enable/Disable Quick Chip for KeyBoard Emulation (QCKB) on the Augusta?



Terminal entry mode (9F39) is returning the incorrect value. How come? How do I resolve this?  

...